Width | 142 |
---|---|
Height | 125 |
Depth | 48 |
Suitable for safety functions | No |
Number of analogue inputs | 16 |
Number of analogue outputs | 0 |
Voltage type of supply voltage | DC |
Supporting protocol for LON | No |
Number of HW-interfaces industrial Ethernet | 0 |
Number of HW-interfaces RS-232 | 0 |
Number of HW-interfaces RS-422 | 0 |
Number of HW-interfaces RS-485 | 0 |
Number of HW-interfaces serial TTY | 0 |
Number of HW-interfaces parallel | 0 |
Number of HW-interfaces other | 0 |
Supporting protocol for TCP/IP | No |
Supporting protocol for ASI | No |
Supporting protocol for PROFIBUS | No |
Supporting protocol for CAN | No |
Supporting protocol for INTERBUS | No |
Supporting protocol for KNX | No |
Supporting protocol for MODBUS | No |
Supporting protocol for Data-Highway | No |
Supporting protocol for DeviceNet | No |
Supporting protocol for SUCONET | No |
Supporting protocol for other bus systems | No |
Input, current | Yes |
Input, voltage | Yes |
Input, resistor | No |
Input, resistance thermometer | No |
Input, thermocouple | No |
Input signal, configurable | Yes |
Output, current | No |
Output, voltage | No |
Output signal configurable | No |
Resolution of the analogue inputs | 12 |
Resolution of the analogue outputs | 0 |
Type of electric connection | Screw connection |
Rail mounting possible | Yes |
Explosion safety category for gas | None |
Explosion safety category for dust | None |
Fieldbus connection over separate bus coupler possible | Yes |
System accessory | Yes |
Appendant operation agent (Ex ia) | No |
Appendant operation agent (Ex ib) | No |
Degree of protection (IP) | IP20 |
Supporting protocol for SERCOS | No |
Supporting protocol for INTERBUS-Safety | No |
Category according to EN 954-1 | 1 |
Number of HW-interfaces PROFINET | 0 |
Number of HW-interfaces Wireless | 0 |
Front build in possible | Yes |
Rack-assembly possible | Yes |
Wall mounting/direct mounting | Yes |
Radio standard Bluetooth | No |
Radio standard WLAN 802.11 | No |
IO link master | No |
Performance level acc. to EN ISO 13849-1 | None |
Supporting protocol for AS-Interface Safety at Work | No |
Supporting protocol for DeviceNet Safety | No |
Supporting protocol for EtherNet/IP | No |
Supporting protocol for Foundation Fieldbus | No |
Supporting protocol for PROFINET CBA | No |
Supporting protocol for PROFINET IO | No |
Supporting protocol for PROFIsafe | No |
Supporting protocol for SafetyBUS p | No |
Supply voltage AC 50 Hz | 0 - 0 |
Supply voltage AC 60 Hz | 0 - 0 |
Supply voltage DC | 24 - 24 |
Analog inputs configurable | Yes |
Analog outputs configurable | No |
Radio standard GPRS | No |
Radio standard GSM | No |
Radio standard UMTS | No |
SIL according to IEC 61508 | None |